What Is Timecode? SMPTE, LTC and Time-of-Day Clocks in Live Production
Timecode is a frame-accurate time label, written HH:MM:SS:FF, that marks every frame of video or audio so machines can locate and synchronise material. SMPTE timecode is the standard format, and LTC carries it as an audio signal. Show clocks and stage timers usually display time of day, not frames.
What is timecode?
Timecode is a time label attached to every frame of video or audio, written as hours, minutes, seconds and frames (HH:MM:SS:FF). A reading of 18:59:30:12 means 18 hours, 59 minutes, 30 seconds and frame 12. Machines use timecode to find exact frames and to stay in step with each other.
The Society of Motion Picture and Television Engineers defines the standard, known as SMPTE timecode, in its ST 12 family of documents. Recorders, playback servers, lighting desks, audio workstations and show control systems all read it.
Timecode converter
Convert between timecode, frames and seconds at common frame rates, including 29.97 and 59.94 drop-frame.
Which timecode formats exist?
Timecode exists in several carriers and frame rates. Crews meet three carriers most often: LTC, VITC and MIDI timecode.
| Format | How it travels | Typical use |
|---|---|---|
| LTC (linear timecode) | Audio-frequency signal on an audio cable or track | Syncing recorders, lighting and playback |
| VITC (vertical interval timecode) | Inside the video signal's blanking interval | Reading timecode from paused tape |
| MTC (MIDI timecode) | MIDI messages | Music software and show control |
| Embedded timecode | Inside SDI or file metadata | Modern cameras and video servers |
Common frame rates are 24, 25, 29.97 and 30 frames per second, plus 23.98 for HD film workflows. Europe and other former PAL regions use 25. North America uses 29.97 for broadcast video.
What is drop-frame timecode?
Drop-frame timecode is a counting method that skips frame numbers 0 and 1 at the start of each minute, except every tenth minute, at 29.97 frames per second. It exists because 29.97 frames per second runs slightly slower than a 30-frame count. Skipping 18 frame numbers every 10 minutes keeps one hour of timecode equal to one hour of real time. No picture frames are removed.
How does timecode relate to show clocks?
Timecode and show clocks answer different questions. Timecode answers "which frame is this?" A show clock answers "what time is it, and how long is left?"
Many live productions set their timecode generator to time of day. The timecode on the playback server then matches the clock on the wall, minus the frames. Producers and presenters read the time-of-day clock and segment countdowns, while machines read the frames. A presenter never needs frame numbers, so a stage display shows HH:MM:SS at most.
Show timers synchronise across screens in a different way. Free Stage Timer uses a server-authoritative clock and measures each screen's offset with NTP-style pings, so all displays agree within about 50 to 100 milliseconds on a normal network. That margin equals a few video frames, so it is not frame-accurate, yet it is more than enough for a speaker countdown. Crews that need frame-accurate triggers use show control software that reads timecode and then fires timer actions through the timer API and integrations.
What else should you know about timecode?
Timecode connects to back-timing, playback and venue wiring. The notes below cover related topics.
Timecode and back-timing
Back-timing uses time-of-day values, not frames. A producer who back-times from a 19:00:00 hard out works in seconds, as shown in the back-timing explanation.
Showing time of day to presenters
Presenters and floor managers read time of day in hours, minutes and seconds, never in frames. A large time-of-day display beside the countdown helps talent hit a fixed clock time, such as a network join at 19:00:00. The display options for this mode, including 12-hour and 24-hour formats, are on the time of day clock for stage displays page.
Wiring LTC around a venue
LTC travels like audio, through audio cables, patch bays and distribution amplifiers. Keep it away from compressors, equalisers and noise reduction, because processing corrupts the signal.
When timecode is not needed
Talks, webinars and most livestreams do not need timecode. A shared time-of-day clock and segment countdowns cover their timing. More broadcast timing topics are listed in the broadcast timing guide index.
Frequently asked questions
What does SMPTE timecode mean?
SMPTE timecode is the time-labelling standard defined by the Society of Motion Picture and Television Engineers. It labels each frame as hours, minutes, seconds and frames.
What is LTC timecode?
LTC, or linear timecode, carries SMPTE timecode as an audio-frequency signal. It runs over normal audio cables and can be recorded on an audio track.
What is drop-frame timecode?
Drop-frame timecode skips certain frame numbers at 29.97 frames per second so the timecode stays aligned with real clock time. No video frames are actually removed.
Does a stage timer need timecode?
Most stage timers do not need timecode. They need an accurate time-of-day reference shared by every screen, which network time sync provides.